> For the complete documentation index, see [llms.txt](https://www.parapathology.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://www.parapathology.com/laboratory-management/microscopy.md).

# Microscopy

## Cover Glass Optics & Metrology: Glass vs. Polymer Film

Cover and mounting media form part of the microscope optical path; thickness, refractive index and surface geometry should be compatible with the intended objective and application.

* \[\[Study on the Performance of Different Cover Glasses in Microscopy]]: Leica Biosystems-commissioned, single-site optical study (September 2025; source page updated October 17, 2026) of specific glass and Sakura tape preparations. Measured surface roughness, deformation, refractive-index differences and birefringence; the **5–20% local MTF contrast reduction at mid-range spatial frequencies** and local test-chart resolution degradation were **Zemax predictions using simplified scanner optics**, not clinical WSI results. The report expects no birefringence-related image effect at moderate-NA brightfield; high-NA/polarization effects may occur. Small samples and optical-model limitations constrain interpretation. Diagnostic accuracy, patient outcomes, rescan rates and AI performance were not assessed.

## OpenFlexure Microscope: 3D-Printable Robotic Microscopy

Open-source, 3D-printable robotic digital microscope featuring sub-100 nm positioning precision via monolithic compliant flexure mechanics, RMS DIN finite/infinity optics, Sangaboard motor control, Python REST API, automated whole-slide scanning, and validated applications in parasitology and telepathology — see [OpenFlexure Microscope](https://www.parapathology.com/computational-digital-and-mathematical-pathology/digital-pathology-software/openflexure-microscope.md) and \[\[Robotic microscopy for everyone: the OpenFlexure Microscope]].

## SlidePrep: Counting-Chamber Reticle Removal & Tiled WSI Stitching

Open-source pipeline for digitizing counting-chamber acquisitions (Sedgwick-Rafter, Neubauer, Malassez, Bürker hemocytometers, and eyepiece micrometer reticles) into calibrated whole-slide images (Rodriguez-Conde et al., *SoftwareX* 2026). Detects etched focal-plane grid lines via 3-class multi-level Otsu thresholding and Random Forest contour filtering, reconstructs occluded specimens via LaMa Fourier-convolution inpainting, and stitches calibrated multi-channel OME-TIFF mosaics with ASHLAR alongside a global inpainting provenance mask (`_inpaint_mask.tif`) — see \[\[SlidePrep]] and \[\[SlidePrep: artifact removal, reconstruction, and visualization of whole-slide images from tiled microscopy acquisitions]].

## <http://www.olympusmicro.com>

## <http://www.microscopy-uk.org.uk/index.html>

## <https://www.microscopyu.com/>

## 10 Tips for Microscope Care....Remember to PM your Scopes.

<https://www.linkedin.com/pulse/10-tips-microscope-careremember-pm-your-scopes-joseph-colao-2>

## [How to Clean and Sterilize Your Microscope](https://www.olympus-lifescience.com/discovery/how-to-clean-and-sterilize-your-microscope)

<https://www.olympus-lifescience.com/discovery/how-to-clean-and-sterilize-your-microscope>

## A 50-cent microscope that folds like origami

<https://www.ted.com/talks/manu_prakash_a_50_cent_microscope_that_folds_like_origami>

#### Oküler mikrometre

{% embed url="<https://www.youtube.com/watch?v=HaqgCtA-ioI>" %}

Özet olarak 4x OFN22 oküler ile görünen alan 22mm ve mikrometredeki ölçüm 4x'te birebir. Diğer okülerler için dönüştürme yapmak gerekiyor.